National purchasing consultation hotline+86 13600030409

DECS-250-LN2SN1N Basler AVR Regulator

¥676.00
Basler DECS-250-LN2SN1N is a full digital excitation control system (AVR, Automatic Voltage Regulator) adopting high-performance microprocessor design. It realizes closed-loop voltage regulation, reactive power control, power factor adjustment and comprehensive generator protection for synchronous generators and synchronous motors. Equipped with multi-limiting functions and complete fault protection logic, it stabilizes generator terminal voltage under variable load fluctuation, improves power grid operation stability, and supports redundant system matching. Widely applied in thermal power, hydropower, diesel genset, marine power and distributed power generation projects.

Basler DECS-250-LN2SN1N Product Specification
Basic Information
Brand: Basler Electric
Model: DECS-250-LN2SN1N
Order Number: DECS-250-LN2SN1N
Product Name: Digital Excitation Control System / AVR Regulator
Origin: United States
HS Code: 8538909200
Dimensions: 250mm × 145mm × 71mm (L×W×D)
Weight: 1.2kg


Input & Output Electrical Parameters
Input
1. Auxiliary Control Power Input: 24/48VDC wide range power supply, power consumption ≤75W
2. Generator Voltage Sensing Input: Single/3-phase AC 100~600VAC, 40~500Hz, True RMS sampling
3. Generator Current CT Input: 1A/5AAC rated current input, burden<1VA
4. Analog Remote Setpoint Input: ±10VDC, 4~20mA analog signal for remote parameter adjustment
5. Digital Switch Input: 16-channel isolated dry contact DI, 24VDC signal level for interlock command
6. PMG/Permanent Magnet Generator power input for excitation driving power source
Output
1. Main Excitation DC Output: Continuous rated 20ADC (@55℃), 10-second forced current 40ADC
2. Relay Digital Output: 11 programmable Form-A relay contacts + 1 watchdog Form-C contact; contact rating 7A@250VAC/125VDC for alarm, trip and status feedback
3. Communication Output: 100Base-T Ethernet, dual RS485 Modbus, USB debugging port
4. Analog Status Output: 0~10VDC/4~20mA signal for excitation current/voltage external monitoring
5. Redundancy interlock signal output for dual DECS parallel operation
Environmental Specification
Operating Temperature: -40℃ ~ +70℃
Storage Temperature: -40℃ ~ +85℃
Working Humidity: 5%~95% RH, non-condensing
Protection Class: IP20, conformal coated PCB
Mounting Mode: Cabinet panel embedded installation




    Customers reviews

    There are no reviews yet.

    Be the first to review “DECS-250-LN2SN1N Basler AVR Regulator”

    Your email address will not be published. Required fields are marked *

    Copyright © 2024-2026 shanxi runsheng import and export Co.,Ltd. all rights reserved.

    Add Your Heading Text Here

    Search for products

    Back to Top
    Product has been added to your cart
    phone: +86 13600030409
    email: kenen168@gmail.com